Simple High Voltage station ≤ 10KV type A884-A1296

General Description

Poste Haute Tension A1296

The A884-A1296 type unit is a simple electromechanical high-voltage generator.

The device is particularly suitable for manual use with clamps or test guns, or for use in an automated system.

Main features

  • High Voltage Test at 3kVAC, 5kVAC or 10kVAC max (depending on the model chosen)
  • High Voltage setting via rotary knob on the front panel
  • Analog display of the High Voltage measurement on the front panel
  • Analog display of the Leakage Current measurement on the front panel
  • Adjustable tripping threshold (5 to 50mA or 10 to 100mA depending on the version)
  • In case of fault : tripping, audible and visual alarm
  • Burning function available (2-3s delayed tripping type A513 or continuous burning type A884)

 

Technical specifications

Power Supply 230 V / 50 Hz + ground
Presentation standard 19″ case
High-voltage AC test

Voltage setting and measurement

 

Leakage current measurement

Trip threshold

Test duration

Burn function

Ground reference

Test start mode

Results recording

 

Adjustable up to 3KVAC / 5KVAC / 10KVAC max depending on the model chosen

Digital display with accuracy as a percentage of the value (2.5 to 3.5%) or a percentage of the range (1.5 to 2.5%)

Digital display with accuracy as a percentage of the value (2.5 to 3.5%) or a percentage of the range (1.5 to 2.5%)

5 to 50mA or 10 to 100mA depending on the version

Electromechanical timer option

Available depending on the version (delayed tripping of 2 to 3 seconds or permanent burning)

Yes

Cycle start button or remote control input depending on version

Without

Items supplied with the device :

  • Instructions for use
  • Verification report with COFRAC-certified connection proof

Accessoires d’utilisation disponibles :

  • Test cables
  • Ground continuity tester
  • Fault simulation box
  • Test cages