SCHLEICH GLP1 and GLP2 Leakage Current Meter

Description générale

GLP1 and GLP2 type stations are leakage current measurement stations of electromechanical design.

The devices are particularly suitable for manual use with clamps or test guns or for use in an automatic system.

Main Features

  • Measurement of contact current and current in the protective conductor (EN60990 standard)
  • Voltage source : 0 to 250VAC
  • Leakage current measurement : 1mA and 10mA ranges
  • Maximum current consumption : 5A – Isolated source
  • Analog display of voltage/current measurements: Class 1.5
  • Programmable parameters via front panel buttons
  • In case of fault : circuit breaker tripping, audible and visual alarm

Technical specifications

Power Supply 230 V / 50 Hz + ground
Presentation standard 19″ box
Leakage current testing

Voltage adjustment and measurement

Leakage current measurement

Fault threshold

 

Adjustable from 0 to 250VAC – Class 1.5 analog measurement

2 ranges of class 1.5 analog measurement: 1mA and 10mA

Adjustable via rotary knob

Operation

Ground reference

Test Launch Mode

Results Recording

 

No

Cycle start button

Without

Items supplied with the unit :

  • User manual
  • Verification report with COFRAC connection certificate

Available accessories :

  • Test cages
  • DLL library and driver software for PC