General Description
Type D1010, D11122, and D1125 workstations are electromechanically designed workstations incorporating a Programmable Logic Controller (PLC) and controlled by a color touchscreen interface.
They allow for the sequencing of various safety tests required by different standards (ground continuity, insulation, high voltage in AC or DC) as well as functional tests (single-phase or three-phase power supply).
All tests are automatically performed with a single product connection.
Main Features
- Continuity Test of Live Parts under 12VAC for detecting phase/neutral connections or short circuits
- Continuity Test under 12VAC – Current of 10A or 25A – Programmable resistance threshold – 4-wires method
- High Voltage Test in AC or DC – With or without superposition – Leakage current up to 100mA AC and 10mA DC
- Insulation Test with fixed voltage 500VDC and maximum resistance 500MΩ – With or without superposition
- Functional Test according to the product’s supply voltage for measuring current consumption or power consumption
- Specific functional test according to customer requirements (product control functions, temperature measurement, rotation measurement, etc.)
- Digital display of measurements on the control panel
- Programming and messaging display on the control panel
- All programmable parameters (voltage, duration, minimum threshold, maximum threshold, ramp Up/down, …)
- In case of fault : audible and visual alarm
- Internal self-check procedure (mandatory and blocking in case of fault)
- Detection of parasitic ground, high voltage presence monitoring during the cycle, contactor redundancy…
- Test recording with USB or Ethernet transfer option
- Simple printing option
- etc. …
Technical specifications
| Power Supply | single-phase 230V / 50 Hz + ground or three-phase 400V + N/ 50 Hz |
| Presentation | Standard electrical cabinet with front-mounted or remote control panel |
| Ground Continuity Test
Test Voltage Test Current Resistance Measurement Test duration
Live Parts Continuity Test Test Voltage Current Measurement Fault Threshold Test duration
AC/DC High Voltage Test Voltage Setting and Measurement Leakage Current Measurement Trip Threshold Test duration Power Overlay
Insulation Test Voltage Setting and Measurement
Insulation Resistance Measurement Fault Threshold Test duration Power Overlay
Functional Test Voltage Setting and Measurement
Current/Power Consumption Measurement Fault Threshold Test duration Other Functions |
12VAC unloaded 10A or 25A 0 to 500mΩ Configurable
Fixed to 12VAC Digital display 0 to3A Configurable minimum and maximum values Fixed < 1 s
Adjustable up to 5KVAC and 6KVDC Digital Display : 0 to 100mAAC and 0 to 10mADC Configurable minimum and maximum values Programmable Yes, depending on the version.
Fixed 500VDC Digital Display Digital Display : 1MΩ to 500MΩ Programmable Programmable Yes, depending on the version.
Single and three-phase according to customer needs (fixed or adjustable) Digital Display Digital Display – Automatic range change depending on version Programmable Programmable Optional additional functions are available |
| Functioning
Ground reference Test launch mode Result recording |
Yes Standardized two-hand control With |
Items supplied with the device :
- Instructions for use
- Verification report with COFRAC-certified connection proof
Available accessories :
- Ground continuity tester
- Two-hand control
- Connection box
- Fault simulation box