General Description
The A1410 type unit is a programmable, automatic, electromechanical high-voltage generator.
The device is particularly suitable for manual use with clamps or test guns, or for use in an automated system.
.
Main features
- High Voltage Test at 3kVAC, 5kVAC, or 10kVAC max (depending on the model)
- High Voltage setting via rotary knob on the front panel
- Digital display of the High Voltage measurement on a touchscreen control panel
- Digital display of the Leakage Current measurement on a touchscreen control panel
- Programming and messaging display on a touchscreen control panel
- Programmable tripping threshold (1 to 100mA depending on the version)
- In case of fault : tripping, audible and visual alarm
- Optional burn-out function (2-3s delayed tripping or continuous burn-out)
- Test recording
Technical specifications
| Power Supply | 230 V / 50 Hz + ground |
| Presentation | standard 19″ case |
| High-voltage AC test
Voltage setting and measurement
Leakage current measurement Trip-out threshold Test duration Burn function Ground reference Test start mode Results recording |
Adjustable up to 3KVAC / 5KVAC / 10KVAC max depending on the model chosen Digital display with accuracy as a percentage of the value (2.5 to 3.5%) or a percentage of the range (1.5 to 2.5%) Digital display with accuracy as a percentage of the value (2.5 to 3.5%) or a percentage of the range (1.5 to 2.5%) 1 to 100mA depending on the version, programmable Programmable Available depending on version Yes Cycle start button or hold button on remote control input depending on version Results with traceability elements (USB or Ethernet transfer) |
Items supplied with the unit :
- User manual
- Verification report with COFRAC connection certification
Available accessories :
- Test cables
- Test guns
- Fault simulation box
- Test cages
- …